EDS-508A/505A Series User’s Manual Featured Functions
3-25
1
st
Trap Server IP/Name
Setting Description Factory Default
IP or Name
Enter the IP address or name of the 1
st
Trap Server used by your network.
None
1
st
Trap Community
Setting Description Factory Default
Character String
Use a community string match for
authentication (maximum of 30
characters).
Public
2nd Trap Server IP/Name
Setting Description Factory Default
IP or Name
Enter the IP address or name of the 2
nd
Trap Server used by your network.
None
2nd Trap Community
Setting Description Factory Default
Character String
Use a community string match for
authentication (maximum of 30
characters).
Public
Inform mode select
Setting Description Factory Default
Retries Enter Inform Retry number 1
Time out Enter Inform Timeout window 1
Private MIB information
Switch Object ID
Setting Description Factory Default
8691.7.9 for EDS-508A;
8691.7.8 for EDS-505A
EDS-508A/505A’s enterprise value Fixed
NOTE: The Switch Object ID cannot be changed.
Using Communication Redundancy
Setting up Communication Redundancy on your network helps protect critical links against failure,
protects against network loops, and keeps network downtime at a minimum.