EDS-508A/505A Series User’s Manual Featured Functions
3-71
Re-Auth
Setting Description Factory Default
Enable/Disable Select to require re-authentication of the client after a
preset time period of no activity has elapsed.
Disable
Re-Auth Period
Setting Description Factory Default
Numerical
(60-65535 sec.)
Specify how frequently the end stations need to reenter
usernames and passwords in order to stay connected.
3600
802.1X
Setting Description Factory Default
Enable/Disable Select the option under the 802.1X column to enable
IEEE 802.1X for one or more ports. All end stations
must enter usernames and passwords before access to
these ports is allowed.
Disable
802.1X Re-Authentication
The EDS can force connected devices to be re-authorized manually.
802.1X Re-Authentication
Setting Description Factory Default
Enable/Disable Select the option to enable 802.1X Re-Authentication Disable