ioLogik E1200 Series RESTful API Default Address Mappings
C-3
RESTful API Name Description Access
/api/slot/0/io/ai aiValueRaw AI - raw value read-only
/api/slot/0/io/ai aiValueScaled AI - scaled value read-only
/api/slot/0/io/ai aiValueRawMin AI - minimum raw value read-only
/api/slot/0/io/ai aiValueRawMax AI - maximum raw value read-only
/api/slot/0/io/ai aiValueScaledMin AI - minimum scaled value read-only
/api/slot/0/io/ai aiValueScaledMax AI - maximum scaled value
read-only
/api/slot/0/io/ai aiResetMinValue AI - reset minimum value
(1: RESET)
read-write
/api/slot/0/io/ai aiResetMaxValue AI - reset maximum value
(1: RESET)
read-write
/api/slot/0/io/ai aiStatus AI - status (0: normal, 1:
burnout, 2: over range, 3.
under range)
read-only
/api/slot/0/io/ai aiBurnoutValue AI - burnout value read-only
/api/slot/0/io/ai/0/aiValueRaw aiValueRaw AI - raw value read-only
/api/slot/0/io/ao
/api/slot/0/io/ao aoIndex AO - index read-only
/api/slot/0/io/ao aoMode AO - mode (0: 0-10 V, 1:
4-20mA, 2: 0-20 mA)
read-only
/api/slot/0/io/ao
aoValueRaw
AO - raw value
read-write
/api/slot/0/io/ao aoValueScaled AO - scaled value read-only
/api/slot/0/io/ao/0/aoValueRaw aoValueRaw AO - raw value read-write
/api/slot/0/io/rtd
/api/slot/0/io/rtd rtdIndex RTD - index read-only
/api/slot/0/io/rtd rtdSensorType RTD - sensor type read-only
/api/slot/0/io/rtd rtdValueEngineering
Multiplied
RTD - engineering
multiplied value
read-only
/api/slot/0/io/rtd rtdValueEngineering
MultipliedMin
RTD - engineering
multiplied minimum value
read-only
/api/slot/0/io/rtd rtdValueEngineering
MultipliedMax
RTD - engineering
multiplied maximum value
read-only
/api/slot/0/io/rtd rtdValueScaled RTD - scaled value read-only
/api/slot/0/io/rtd rtdValueScaledMin RTD - minimum scaled
value
read-only
/api/slot/0/io/rtd rtdValueScaledMax RTD - maximum scaled
value
read-only
/api/slot/0/io/rtd rtdResetMinValue RTD -
reset minimum value
(1: RESET)
read-write
/api/slot/0/io/rtd rtdResetMaxValue RTD -
reset maximum value
(1: RESET)
read-write
/api/slot/0/io/rtd/0/rtdValue
EngineeringMultiplied
rtdValueEngineering
Multiplied
RTD - engineering
multiplied value
read-only
/api/slot/0/io/tc
/api/slot/0/io/tc tcIndex TC - index read-only
/api/slot/0/io/tc tcSensorType TC - sensor type read-only
/api/slot/0/io/tc tcValueEngineering
Multiplied
TC - engineering multiplied
value
read-only
/api/slot/0/io/tc tcValueEngineering
MultipliedMin
TC - engineering multiplied
minimum value
read-only
/api/slot/0/io/tc tcValueEngineering
MultipliedMax
TC - engineering multiplied
maximum value
read-only
/api/slot/0/io/tc tcValueScaled TC - scaled value read-only

Table of Contents

Other manuals for Moxa Technologies ioLogik E1211

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies ioLogik E1211 and is the answer not in the manual?

Moxa Technologies ioLogik E1211 Specifications

General IconGeneral
BrandMoxa Technologies
ModelioLogik E1211
CategoryI/O Systems
LanguageEnglish

Related product manuals