6 Mounting
Maschinenfabrik Reinhausen GmbH 202328 4001150/12 ENMSENSE
®
DGA 2/3
9. Mount the closed ball valve on the transformer and align via the elongated
holes so that the locking lever is at the top. Use fastening materials made
of stainless steel A4 in the strength category -70.
Figure11: Mounting the closed ball valve
Flange Screws WAF Nm
DN50 PN6 M12 A4-70 19/18 62
DN50 PN16 M16 A4-70 24 150
DN80 PN16 M16 A4-70 24 150
Grease the steel clamping ring regularly with Vaseline or the grease sup-
plied to protect it against corrosion; see also chapter Ensuring offshore ca-