6 Mounting
Maschinenfabrik Reinhausen GmbH 2023 314001150/12 EN MSENSE
®
DGA 2/3
4. NOTICE! Make sure the oil extraction adapter belongs to this device. If
the standard version and the offshore version are mixed up, the oil extrac-
tion connection and the adapter can become damaged. Push the supplied
oil extraction adapter into the opening until it audibly snaps into place.
Figure15: Connecting the oil extraction adapter
5. Open the oil extractor valve so that the air present can dissipate during
further assembly.
Figure16: Opening the oil extraction adapter
6. Insert the measuring pipe into the closed ball valve.
If the device is an offshore version, the steel clamping ring on the ball valve
is to be greased prior to mounting the device (see chapter Ensuring offshore
capability [►Section 6.4, Page 47]).