ALTAIR 5X PID
59
Technical Specifications
US
6Technical Specifications
6.1 Factory-set Alarm Thresholds and Setpoints
Weight 0.45 kg (1 lb.) - device with battery and clip
Dimensions (cm)
Length: 6.7 inches (169.9mm)
Width: 3.5 inches (89.7mm)
Height: 2.0 inches (51.4mm)
Alarms LEDs, audible alarm, vibrating alarm
Volume of audible alarm 95 dBa at 30cm with fully charged battery, average
Display Color
Battery types Rechargeable Li ION battery
Charging time
≤ 6 hours
The maximum safe area charging voltage
Um = 6.7 Volts DC
Normal Temperature range -10 °C to 40 °C (14 °F to 104 °F)
Extended Temperature range -20 °C to 50 °C (-4 °F to 122 °F)
Humidity range
15 - 90 % relative humidity, non-condensing,
5 - 95 % RH intermittent
Atmospheric pressure range 80 kPa to 120 kPa (11.6 to 17.4 PSIA)
Ingress protection IP 65
Measuring methods
Combustible gases - Catalytic sensor
Oxygen and Toxic gases - Electrochemical sensor
Volatile Organic Compounds - PID sensor
Warranty See chapter 1.4
Measuring Range
CIO
2
0-1.00 ppm NH
3
0-100 ppm
Cl
2
0-10 ppm NO 0-200 ppm
CO 0-2000 ppm NO
2
(S20) 0-20.0 ppm
CO - HC 0-10,000 ppm NO
2
(XCell) 0-50.0 ppm
Combustible
0-100 % LEL
0-5.00 % CH
4
O
2
0-30 % Vol.
H
2
S 0-200 ppm PH
3
0-5.00 ppm
H
2
S - LC 0-100 ppm PID 0-2000 ppm
HCN 0-30 ppm SO
2
0-20.0 ppm
Check the device or calibration certificate for exact alarm levels as they vary depending
on national or corporate regulations.

Table of Contents