• The LCD will show all segments for a display test.
• The software version number will display.
The D
yna-Link 2 is ready for use.
2.2 Zero
Takes out small deviations in zero when the Dyna-Link 2 is unloaded. See Section 3.6
for zeroing (Taring) package or pallet weights.
. The display reads 0 (or 0.0 or 0.00, etc).
The backup memory stores the zero reading, and can restore it even if
power fails.
Zero - Rules for Use:
• Works in GROSS mode or NET mode. Zeroing while in NET mode will zero
the gross tension causing the display to show the negative tare value.
• The unit must be stable within the motion window, it will not zero until the
stable ann
unciator is on.
• The unit will “remember” that it has a zero
request for two seconds. If motion
clears in that time, it will zero.
• The unit will accept a zero setting over the full range of the Dyna-Link. Zero
setti
ngs above 4% of full Dyna-Link will subtract from the overall capacity.
For example, if you zero out 100 lb on a 1000 lb Dyna-Link, the overall
capacity will reduce to 900 lb plus the allowed over-range amount.