Fault code No. Full designation Meaning Action
Related
parameter
No.
139 L1 TE BUFFER TEST
Supply voltage of tempera-
ture sensors faulty.
Contact Serv-
ice.Check sen-
sors;Replace ECU. -
140 TE BUF. ECU DEFECT
Supply voltage of tempera-
ture sensors faulty.
Contact Serv-
ice.Check sen-
sors;Replace ECU. -
142 BANK1 ECU DEFECT
Power output stage for sole-
noid valve activation on
bank 1 faulty; engine does
not start. Replace ECU. -
144 BANK2 ECU DEFECT
Power output stage for sole-
noid valve activation on
bank 2 faulty; engine does
not start. Replace ECU. -
145
15V_GOOD ECU DE-
FECT
Voltage supply is defective;
automatic engine shutdown. Replace ECU. -
146 L1 AD-TEST1 SUPPLY
Supply voltage of A/D con-
verter too low. Replace ECU. -
147 AD-TEST1 ECU DEFECT
Electronic fault; automatic
engine shutdown. Replace ECU. -
148 L1 AD-TEST2 SUPPLY
Supply voltage of A/D con-
verter too low. Replace ECU. -
149 AD-TEST2 ECU DEFECT
Internal electronic fault; au-
tomatic engine shutdown. Replace ECU. -
150 L1 AD-TEST3 SUPPLY
Internal electronic fault; au-
tomatic engine shutdown. Replace ECU. -
151 AD-TEST3 ECU DEFECT
Internal electronic fault; au-
tomatic engine shutdown. Replace ECU. -
176 AL LifeData Not Avail
Alarm configuration; No (ap-
propriate) LifeData backup
system available, ECU reset
after expiration of time-out
period. Contact Service.
2.4000.00
4
177
AL LifeData Restore In-
complete
Alarm configuration; This er-
ror message is generated if a
CRC is faulty during a data
upload to ADEC (indicated
for each indiv. module). Contact Service.
2.4000.00
6
180 AL CAN1 Node Failure
Alarm configuration; Connec-
tion to one node on CAN bus
1 failed. Contact Service.
2.0500.68
0
181 AL CAN2 Node Failure
Alarm configuration; Connec-
tion to one node on CAN bus
2 failed. Contact Service.
2.0500.68
1
182
AL CAN Incorr. Parame-
triz.
Alarm configuration; Incor-
rect parameter values en-
tered in data record. Contact Service.
2.0500.68
2
64 | Troubleshooting | M015695/03E 2013-03
TIM-ID: 0000033662 - 001

Table of Contents