Mod. 6609d-6612d: Automatic Forms Cutter 13.12.2006
-34-
Example 2: The same 6 functions as in example 1 are to be carried out: deflector unit 1,2,3,
collector, enveloping and stop.
In order to limit the number of lines to be read, it is also possible to allocate one function
to several marks.
E.g. If there is a mark in lines 2 and 3 at the same time, the form should be sent to
deflector unit 3 (see illustration p. 38)
Where several marks are to be used, the 5-digit code number is worked out by adding them together. Thus the
number for deflector unit 2 + deflector unit 1 + AL = 2 + 4 + 1 = 7.
The 5-digit code number for enveloping and AL is thus 00017. Let us now consider the whole block of marks as a
complete unit. The adjustment line contains the first mark, since it is the first to pass the reading head. Deflector
unit 2 is thus the second mark, and so on. We can use Table 1 to find the appropriate 5-digit code number for any
combination of marks. In our example these are:
1. AL + collector = 00009
2. AL + enveloping = 00017
3. AL + deflector unit 1 = 00005
4. AL + deflector unit 2 = 00003
5. AL + deflector unit 3 = 00007
6. AL + stop = 00025
In example 2 input should be carried out as follows
(input for the function is described below):
In posiiton #32 it is possible to output one or more functions for forms which have caused ar eading error. The
function “select” is recommended, if there is a def lector unit available. The "Code" column in line 32 is here always
00000. In the "Function" column one or more functions can now be entered (as in numbers #00 - #31). See also
the function tables. If a read error occurs, i.e. none of the codes in #00 - #31 is recognised as valid, then the
function given in line #32 will be output for the form which caused the reading error. The machine will be stopped
and “read error” will appear in the display.
Suggestion for function in line #32: Deflector unit 1 = 5-digit number 00004
The 5-digit number for the code remains 00000
3.3.2.3 Entering the 5-digit number for the functions
We shall now allocate a function to the marks on the form which are to be detected by the reading head.
Table 2 (page 35) for converting functions (Fnc) into 5-digit numbers is used in the same way as Table 1.
Each combination of marks represents one or more functions. To go back to our examples, we have here s ix
different functions (enveloping, collector, deflector unit 1, deflector unit 2, deflector unit 3 and s top). Müller online
machines have fixed functions!
Input for the function is described in the examples above.