64 Part Number: WBL-95-156 REV002
Maintenance Section 4
26. Reassemble the ice chute by placing it back into the
bin lid opening, pushing it back on to the top of the
evaporator and tightening the large wing clamp
loosened in step 16.
27. Put ice damper flap and the ice chute strainer back into
place, then tighten the ice wiper nut down on to the
top of the evaporator.
28. Spray and wipe down the ice chute assembly with
sanitizer solution.
29. Secure the clear ice chute cover on to the ice chute,
removed in step 13, with the two (2) floating cover nuts.
30. Plug unit back into power source and power ON the unit
by moving the power rocker switch to the ON position.
31. After approximately 15 minutes the compressor will kick
on and the ice machine will make ice with the sanitizer
solution then begin to deposit the ice in the bin.
NOTE: Do not allow the sanitizer solution level to drop
below the sensing probes. The ice machine will start a 20
minute delay period if the sensing probes lose contact with
the water for more than 10 seconds. If this happens refill the
reservoir and power cycle the unit to start over.
32. Make ice for 20 minutes, adding sanitizer solution as
the water level in the reservoir drops using the pitcher/
cups set aside earlier.
33. After making ice for 20 minutes evacuate all sanitizer
solution from the reservoir and evaporator by entering
the Service screen> Service Outputs> Cleaning and
toggling the Ice Maker Dump Valve ON until all solution
has been emptied from the system then toggle OFF.
34. Power down the unit by moving the power rocker
switch to the OFF position.
35. Reconnect the water supply line quick connect in the
back of the unit, place the top and left panels back onto
the unit
36. Power ON the unit by moving the power rocker switch
to the ON position.
NOTE: Startup delay after power cycle will take approximately
15 minutes before the compressor will turn on.
37. After the startup delay, allow the ice machine to make
ice for 20 minutes.
n
Warning
This ice production will contain residual cleaning
chemicals and must be discarded.
38. After 20 minutes power cycle the unit by turning the
rocker switch to the OFF position, waiting 30 seconds
then ON.
39. Empty all ice from the ice bin by entering the Service
screen> Service Outputs> Dispense & Blend and toggling
the Ice Motor ON until all ice has been dispensed from the
ice bin, discard all ice produced.
40. Logout of the Service screen and allow the ice maker to make
ice for 20 minutes before putting the unit back into use.
NOTE: Ice Calibration may be required. See “Product, Ice, &
Water Calibration on page 31