Configuration/settings
User manual 55530_hdb_en_16 115 / 156
Setting up the MRP cy-
cle times
As soon as the media redundancy has been set, the IO cycle times for each
module must be parameterized.
Depending on the PLC, the RT requirements and the system structure, the IO
cycle times and factors have to be set in the following window.
Fig. 8-43: Setting up the MRP cycle times
1 | To the menu item
Navigate to the menu item PROFINET interface | Advanced options |
Real-time settings | IO cycle.
2 | Set the values for: Update time and Accepted update cycles without IO
data.