EasyManua.ls Logo

Nabco GT 710 - User Manual

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
S82 W18717 Gemini Drive
Muskego, Wisconsin 53150
Phone: (877) 622-2694
Fax: (888) 679-3319
www.nabcoentrances.com
Technical Support: (866) 622-8325
Part #15-10683
Rev. 9/24/14
Low Energy Operator Swing Door Systems
Side Load Units: GT 710 and 8710
DN 1078
GT710 SIDE LOAD UNIT
Hinged Side
Access Panel
GT8710 SIDE LOAD UNIT
Hinged Side
Access Panel
WARNING
• Turn OFF all power to the Automac Door if a Safety System is not working.
• Instruct the Owner to keep all power turned OFF unl correcve acon can be achieved by a NABCO
trained technician. Failure to follow these pracces may result in serious consequences.
• NEVER leave a Door operang without all Safety detecon systems operaonal.

Other manuals for Nabco GT 710

Questions and Answers

  • J
    Julie HolderSep 1, 2025
    How to correct the direction of a Nabco GT 710 Gate Opener door?
    • J
      Jesse FisherSep 1, 2025
      If your Nabco Gate Opener door moves in the wrong direction, check the polarity of the motor input wires at the connector on the motor and reverse the motor leads.
  • C
    Carlos WaltersAug 31, 2025
    What causes a Nabco Gate Opener door to slam open?
    • L
      Lisa GriffinAug 31, 2025
      A Nabco Gate Opener door slamming open can be caused by the back check speed not being adjusted or the magnet not being in the proper location. Adjust the Back Check potentiometer or relocate the Magnet to resolve this.
  • W
    William RushAug 30, 2025
    What to do if Nabco Gate Opener door does not stay tightly closed?
    • S
      Stephanie RossAug 30, 2025
      If your Nabco Gate Opener door doesn't stay tightly closed, it could be due to incorrect preload on the swing arm; position the arm at 45 degrees. Alternatively, excessive building stack pressure may be the cause; in this case, upgrade the operator unit to a GT 500.
  • L
    lthompsonAug 29, 2025
    How to fix a Nabco GT 710 Gate Opener door that slams closed?
    • K
      Kevin JacksonAug 29, 2025
      If your Nabco Gate Opener door slams shut, the main speed on the hydraulic closer may not be adjusted properly. Turn the main speed in the direction of the Turtle to resolve this issue.
  • S
    Scott ThompsonAug 28, 2025
    Why does Fuse 1 (F1) blow when the Nabco Gate Opener door is triggered to open?
    • T
      Tamara SpenceAug 28, 2025
      If Fuse 1 (F1) blows when the door open is triggered on your Nabco Gate Opener, it may be due to the door activation device's power consumption. If the current draw exceeds 0.5 amps at 24 VAC, replace it with a lower draw sensor.
  • A
    Amanda ButlerAug 27, 2025
    What to do if my Nabco GT 710 Gate Opener does not function?
    • A
      amanda79Aug 27, 2025
      If your Nabco Gate Opener isn't working, start by checking Fuse 2 (F2) and replace it if necessary. Also, verify that there is 120 VAC at Connector J5. If the power supply is good, check the connection to the motor and replace the motor if needed. Check the power to the activation device at Connector J2; if the current exceeds 0.5 amps at 24 VAC, replace it with a lower draw sensor. Finally, check Fuse 1 (F1); if it's blown, replace it. If F1 is okay, check the power to the activating devices at J2, and if the voltage is too low, reduce the accessory load.
  • B
    Blake ArcherAug 27, 2025
    How to fix MPU Error on Nabco Door Opening System?
    • T
      travisbrownAug 27, 2025
      If the MPU Error occurs repeatedly on your Nabco Door Opening System, replace the Opus Control.
  • C
    Catherine SmithAug 25, 2025
    Why is my Nabco Door Opening System showing '62 Sensor Error', '6B Sensor Error', or 'SWL Sensor Error'?
    • T
      Thomas LewisAug 26, 2025
      If your Nabco Door Opening System is showing '62 Sensor Error', '6B Sensor Error', or 'SWL Sensor Error', it may indicate that the hand-shake for the safety sensor is not working properly, or the sensor could be detecting an internal error. Check the Opus for input/output settings, harnesses, and sensor status.
  • G
    Glen DavisAug 25, 2025
    What does 'Recycle Warning' mean on my Nabco Door Opening System and how to fix it?
    • L
      Lisa BanksAug 25, 2025
      If your Nabco Door Opening System displays a 'Recycle Warning', check the doorway and door resistance. If both are normal, adjust the opening and closing recycle sensitivity.

Summary

Chapter 3: Install the Header

Section 3 b: Prepare the Header

Details steps for preparing the header unit before mounting.

Section 3 c: Prepare the Door Frame

Instructions for preparing the door frame, including measurements and reinforcement.

Section 3 d: Secure Header to the Door Frame

Guides on securing the header to the door frame using screws or lag bolts.

Chapter 4: 110 VAC General Wiring

Chapter 5: Install the First Half of Swing Arm

Section 5 a: Outswing Arm

Instructions for preparing the swing door for an outswing arm installation.

Section 5 b: Inswing Arm

Instructions for preparing the swing door for an inswing arm installation.

Chapter 6: Install the Second Half of Swing Arm

Section 6 a: Set Pre-Load

Details how to set the correct pre-load for the operator spindle.

Chapter 7: Install the Magnets

Chapter 8: Adjustments

Chapter 10: Troubleshooting

Nabco GT 710 Specifications

General IconGeneral
BrandNabco
ModelGT 710
CategoryGate Opener
LanguageEnglish

Related product manuals