STEP 2: AREA OPTIONS: Each relay event can be assigned to Area 1, Area 2 or both Area 1 &
Area 2.
Select the area from Table 2 (shown on next page); enter in corresponding right digit address
location (left digit is not used).
RELAY EVENT OPTIONS
RELAY # AREA Timeout Event ID
L R L R L R L R L R
(•)
(•)
COND.
Step
1
To program, follow the 5 steps below:
STEP 1: RELAY # OPTIONS: The GEM-P1664 supports 8 external relays
from Relay Module RM3008. Multiple events may be "mapped" to each relay,
up to a maximum of 16 events.
Select the relay number from Table 1 (shown on next page); enter in
corresponding right digit address location (left digit is not used).
STEP 3: TIMEOUTS: Each relay event can be assigned a timeout depending on Alarm Type option.
If Alarm Type (see next page) is selected for timeout in minutes or seconds, select the timeout from Table
3 (shown on next page) in minutes or seconds and enter in corresponding address location (left digit and
right digits). To choose seconds or minutes, see step 5A below. 254 is maximum entry.
Continued
STEP 4: EVENT ID CODES: Each relay event can be assigned any of the available event IDs from the table.
Select 2-digit Event ID from Table 4 (see next page); enter in corresponding address locations (left and right digit).
STEP 5: RELAY EVENT CONDITION OPTIONS: Each relay event can be assigned an alarm type; and an activation
condition; also, select a timeout type for each.
5A. Select Alarm Type and Timeout Type from Table 5A (shown on next page); enter in corresponding address location (left
digit).
5B. Select Activation from from Table 5B (shown on next page); enter in corresponding address location (right digit).
Step
2
Step
3
Step
4
Step
5
ADDRESS 1609-1613 (RELAY EVENT 25)
1609 1610 1611 1612
L R L R L R L R L R
(•)
(•)
1613
RELAY # AREA Timeout Event ID COND.
ADDRESS 1614-1618 (RELAY EVENT 26)
1614 1615 1616 1617
L R L R L R L R L R
(•)
(•)
1618
RELAY # AREA Timeout Event ID COND.
ADDRESS 1619-1623 (RELAY EVENT 27)
1619 1620 1621 1622
L R L R L R L R L R
(•)
(•)
1623
RELAY # AREA Timeout Event ID COND.
ADDRESS 1624-1628 (RELAY EVENT 28)
1624 1625 1626 1627
L R L R L R L R L R
(•)
(•)
1628
RELAY # AREA Timeout Event ID COND.
ADDRESS 1629-1633 (RELAY EVENT 29)
1629 1630 1631 1632
L R L R L R L R L R
(•)
(•)
1633
RELAY # AREA Timeout Event ID COND.
ADDRESS 1634-1638 (RELAY EVENT 30)
1634 1635 1636 1637
L R L R L R L R L R
(•)
(•)
1638
RELAY # AREA Timeout Event ID COND.
ADDRESS 1639-1643 (RELAY EVENT 31)
1639 1640 1641 1642
L R L R L R L R L R
(•)
(•)
1643
RELAY # AREA Timeout Event ID COND.
ADDRESS 1644-1648 (RELAY EVENT 32)
1644 1645 1646 1647
L R L R L R L R L R
(•)
(•)
1648
RELAY # AREA Timeout Event ID COND.
[Default = blank (•) blank (•) from
address 1609-1648]
To program, follow the 5 steps below:
Direct Address Program Mode