NAPCO Security Systems
R
GEM-P816 Programming Instructions
Page 13
advance to the data field.
5. Press
015. The numbers 015 will appear on the keypad display indicating the number of
seconds entered.
6. Press
U to save. Address 1417 is now programmed with a 15-second Abort Delay.
7. Press
R and enter another 4-digit address to continue programming--or--press C to exit and re-
sume normal keypad operation.
C) Hexadecimal Format Example
Data such as Report Codes displays and accepts data by means of a Hexadecimal display. Data is entered di-
rectly, by pressing keys 1 – 9,
G0 for zero, and G 1 through G 5 for hex B through F (11-15),
with the cursor automatically moving to the right upon key press. See table below.
EXAMPLE: HEXADECIMAL Format with the GEM-RP1CAe2: Program Chime Timeout to be 2 seconds.
DETERMINE THE DATA ENTRIES
1. Referring to SYSTEM DELAYS & TIMEOUTS in the Programming Worksheets that follow, the Chime Timeout
is located at address 1418. In the "Chime Timeout Options" table, the data entries needed to assign a time-
out of 2 seconds are "blank" and "8".
ENTRY
TOTAL
PRESS
N
KEYPAD
DISPLAYS
ENTRY
TOTAL
PRESS
N
KEYPAD
DISPLAYS
blank
0
8
8
8
1
1
1 9
9
9
2
2
2 10
G 0
0
3
3
3 11
G 1
B
4
4
4 12
G 2
C
5
5
5 13
G 3
D
6
6
6 14
G 4
E
7
7
7 15
G 5
F
HEXADECIMAL ENTRIES
CHIME
ADDRESS 1418
TIMEOUT
(¼sec.)
[Default = 2 ¼sec. = ½ sec.]
DATA ENTRY LOCATION:
Decimal Format
No time yet entered
DATA ENTRY LOCATION:
Decimal Format
Press 0 8 in order to set "Chime
Timeout" to 2 seconds. The "H" on the right
indicates "Hexadecimal" format.
Address
1418
"Chime
Timeout"
1418 - - H 1418 - 8 H
Address
1418
"Chime
Timeout"
2 seconds
CHIME TIMEOUT OPTIONS
TIMEOUT
LEFT RIGHT
blank (•) blank (•) 0 x ¼sec. = 0 sec.
blank (•) 2 2 x ¼sec. = ½ sec.
blank (•) 3 3 x ¼sec. = ¾ sec.
blank (•) 4 4 x ¼sec. = 1 sec.
blank (•) 5 5 x ¼sec. = 1.25 sec.
blank (•) 6 6 x ¼sec. = 1.5 sec.
blank (•) 7 7 x ¼sec. = 1.75 sec.
blank (•) 8 8 x ¼sec. = 2 sec.
F F 255 x ¼sec. = 63.25
DATA ENTRIES

Table of Contents

Other manuals for NAPCO Gemini GEM-P816

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P816 and is the answer not in the manual?

NAPCO Gemini GEM-P816 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P816
CategoryControl Panel
LanguageEnglish

Related product manuals