OUTPUT TURNS OFF UPON DISARM:
Select options for any of the 4 Outputs. By default, the ability to turn off an output upon disarm is not allowed. Enter digit in
address location. NOTE: Dark shaded data value box shows option not available. Press
U to save.
AREA BELL CONTROL OPTIONS (ADDRESS 1473, 1477, 1481, 1485)
1481
PGM1 Output Turns Off upon Disarm
Default
Option: Disarming:
ON
1
PGM1 Output Silenced
OFF
2
RESERVED
1485
PGM2 Output Turns Off upon Disarm
Default
Option: Disarming:
ON
1
PGM2 Burg Output Silenced
OFF
2
RESERVED
1473 Burglary Output Turns Off upon Disarm
Default
Option: Disarming:
ON
1
Burg Output Silenced
OFF
2
RESERVED
1477
Pulsed Burg Output Turns Off upon Disarm
Default
Option: Disarming:
ON
1
Pulsed Burg Output Silenced
OFF
2
RESERVED
Output Turns Off upon Disarm