Chapter 7 PFI
NI USB-621x User Manual 7-2 ni.com
Figure 7-2 shows the circuitry of an output PFI line.
Figure 7-2. USB-621x PFI Output Circuitry
When a terminal is used as a timing input or output signal, it is called PFI x.
When a terminal is used as a static digital input or output, it is called P0.x,
P1.x, or P2.x.
The voltage input and output levels and the current drive levels of the PFI
signals are listed in the NI USB-621x Specifications.
Using PFI Terminals as Timing Input Signals
Use PFI terminals to route external timing signals to many different
USB-621x functions. Each input PFI terminal can be routed to any of the
following signals:
AI Convert Clock (ai/ConvertClock)
AI Sample Clock (ai/SampleClock)
AI Start Trigger (ai/StartTrigger)
AI Reference Trigger (ai/ReferenceTrigger)
•AI Pause Trigger (ai/PauseTrigger)
AI Sample Clock Timebase (ai/SampleClockTimebase)
AO Start Trigger (ao/StartTrigger)
AO Sample Clock (ao/SampleClock)
Timing Signals
Direction Control
I/O Protection
47 kΩ Pull-Down
PFI/DIO Pin
Static DO
Buffer
Isolation
Barrier
(USB-6215/
6216/6218
devices only)
Digital
Isolators

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments USB-621 Series and is the answer not in the manual?

National Instruments USB-621 Series Specifications

General IconGeneral
BrandNational Instruments
ModelUSB-621 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals