VX150 TO VX2 TROUBLESHOOTING MANUAL RESPONDING TO ALARMS
VERSION 2.0 2023-04-20 PAGE 3.1.9
AES1 Unlocked
The AES1 audio input is receiving invalid data
or no data at all.
The AES1 input must be configured as the
main audio source in the active preset for this
alarm to trigger.
This alarm will clear after the AES1 input
receives at least 8 consecutive valid samples.
Check the audio feed connected to the
AES1 input. The most likely cause of this
alarm is a complete interruption in the
AES audio connection to the transmitter.
Check for disconnected cables, or a
failure in upstream equipment.
Swap the input to AES2 and verify the
reception of audio on that port through
the AES2 Left and Right Meters. The
meters will show a N/A value if the
source is unlocked.
AES2 Unlocked
The AES2 audio input is receiving invalid data
or no data at all.
The AES2 input must be configured as the
main audio source in the active preset for this
alarm to trigger.
This alarm will clear after the AES2 input
receives at least 8 consecutive valid samples.
Check the audio feed connected to the
AES2 input. The most likely cause of this
alarm is a complete interruption in the
AES audio connection to the transmitter.
Check for disconnected cables, or a
failure in upstream equipment.
Swap the input to AES2 and verify the
reception of audio on that port through
the AES2 Left and Right Meters. The
meters will show a N/A value if the
source is unlocked.