1. List of Windows Event Logs
Installation Guide (Windows Server 2022)
69
Chapter 3 Appendix
ID
Source Level Message (Description)
Timing when an event is logged Action
All Windows OS ”System Log”
1407
ESMCommonService Error
This is the event which occurred between this system start-up and
the last system stop or system shutdown.
Date : YYYY-MM-DD hh:mm:ss
Event Class : 0x11
Event Code : 0x0D
Status : Critical
Description : All links are down in adapter xxxxx in slot x
When starting system,
or applying Standard Program Package
This event does not affect system operation.
4367
Agentless Management
Service
Error
Description of Event ID 4367, IML Class Code 17, Event Code 13:
All links are down in adapter xxxxx in slot xCheck the connection to
the adapter and validate the connectivity from the server to any
external device, including the cabling. If no problems are found, the
adapter or other connectivity device may need replacement.
When installing an OS, starting system,
or applying Standard Program Package
This event does not affect system operation.
4367
Agentless Management
Service
Error
Description of IML Event ID 4367, Class Code 17, Event Code 12:
Redundancy status changed to decreased by adapter in slot x, port
xIf redundancy decreased, check the connection to the adapter and
validate the connectivity from the server to any external device,
including the cabling. If no problems are found, the adapter or other
connectivity device may need replacement
When installing an OS, starting system, or
applying Standard Program Package
This event does not affect system operation.
4367
Agentless Management
Service
Error
Description of IML Event ID 4367, Class Code 17, Event Code 10:
xxxxx Connectivity status changed to Link Failure for adapter in slot
x, port xIf the connection is lost, then check the physical connection
from the server to its destination device such as interconnect,
blade, switch etc, including any cables. Refer to the NIC issues
flowchart in the Troubleshooting Guide for more information.
When installing an OS, starting system, or
applying Standard Program Package
This event does not affect system operation.
7000
Service Control Manager Error
QLogic Fibre Channel Service service failed to start due to the
following error:
the system cannot find the file specified
Applying Standard Program Package This event does not affect system operation.
37130
ESMCommonService Error
Date : YYYY-MM-DD hh:mm:ss
Event Class : 0x11
Event Code : 0x0A
Status : Critical
Description : xxxxx Connectivity status changed to xxxxx
for adapter in slot x, port x
When starting system,
or applying Standard Program Package
This event does not affect system operation.

Table of Contents

Other manuals for NEC Express5800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Express5800 Series and is the answer not in the manual?

NEC Express5800 Series Specifications

General IconGeneral
SeriesExpress5800
CategoryServer
ProcessorIntel Xeon processors
NetworkGigabit Ethernet, 10 Gigabit Ethernet (Varies by model)
Operating System SupportWindows Server, Linux variants
Form FactorTower, Rackmount (1U, 2U, etc. - varies by model)
MemoryDDR4 ECC DIMM (Capacity varies by model)
StorageSAS/SATA HDD/SSD, NVMe SSD (Configuration varies by model)

Related product manuals