Issue 5.0 UNIVERGE SV8100
1 - 994 Tone Override
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
11-12-03 Service Code Setup (for Service
Access) – Override (Off-Hook
Signaling)
Assign a service code (809 by
default) to be used for Off-Hook
Signaling Override.
MLT, SLT
(default = 809)
11-16-04 Single Digit Service Code Setup
– Intercom Off-Hook Signaling
Assign a one-digit service code
(not assigned by default) to be
used for Off-Hook Signaling.
(default not assigned)
15-02-12 Multiline Telephone Basic Data
Setup – Off-Hook Ringing
For each extension, set Off-Hook
Ringing type: 0 (Muted), 1 (None),
3 (Beep in Speaker), 4 (Beep in
Handset), 5 (Beep in Handset and
Speaker).
0 = Muted Off-Hook
Ringing
1 = No Off-Hook
Ringing
2 = Not Used
3 = Beep in Speaker
(SP)
4 = Beep in Handset
(HS)
5 = Speaker & Handset
Beep
(default = 5)
15-07-01 Programmable Function Keys Assign a function key for Off-Hook
Signaling (code 33).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1