Q-Sig 1 - 813
Conditions
Some QSIG connections require the sending of a Connect Acknowledge IE. To enable this it may be
necessary to enable command 10-03-22 on the PRI circuit configured for QSIG
It may also be necessary to set the following commands:
10-03-17 - enable the sending of ringback tone
20-25-04 - set dial tone to internal (if no dial tone is presented by the PINX)
20-25-07 - set busy tone to internal (if no busy tone is presented by the PINX or is not accompanied by a
ProgressIE #8)
Overview of supported QSIG standards
Default Setting
No ISDN BRI/PRI cards are installed.
System Availability
Terminals
Any Station
Required Component(s)
ISDN PRI/BRI cards
Table 1-16 Overview of Supported QSIG Standards
Abbreviation Brief description ECMA ISO/IEC ETSI
QSIG-BC Basic call at Q ECMA-142/143 ISO/IEC IS
11572
ETSI 300 172
QSIG-NI Number Identification ECMA-148 ISO/IEC IS
14136
ETSI 300 173
QSIG-CLIP Calling Line Identification
Presentation
ECMA-148 ISO/IEC IS
14136
ETSI 300 173
QSIG-COLP Connection Line Identification
presentation
ECMA-148 ISO/IEC IS
14136
ETSI 300 173
QSIG-CLIR Calling/Connected Line
Identification restriction
ECMA-148 ISO/IEC IS
14136
ETSI 300 173

Table of Contents