Issue 5.0 UNIVERGE SV8100
1 - 1100 Voice Mail Integration (Analog)
80-03-05 DTMF Tone Receiver Setup –
Forward twist level
Use to define the various forward
twist levels for the DTMF Tone
Receiver.
0~9 (1dB ~ 10dB)
[default: Type 1~5 =
5 (6dBm)]
80-03-06 DTMF Tone Receiver Setup –
Backward twist level
Use to define the various
backward twist levels for the
DTMF Tone Receiver.
0~9 (1dB ~ 10dB)
[default: Type 1~5 =
0 (1dBm)]
80-03-07 DTMF Tone Receiver Setup – ON
detect time
Use to define the on detect time
for the DTMF Tone Receiver.
1~255 (15+ 15 ms ~
3825 ms)
[default: Type 1~5 =
1 (30ms)]
80-03-08 DTMF Tone Receiver Setup –
OFF detect time
Use to define the off detect time
for the DTMF Tone Receiver.
1~255 (15+ 15 ms ~
3825 ms)
[default: Type 1~5 =
1 (30ms)]
80-04-01 Call Progress Tone Detector
Setup – Detection Level
Use to define the detection levels
for the Call Progress Tone
Detector.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
80-04-02 Call Progress Tone Detector
Setup – Min. Detection Level
Use to define the minimum
detection levels for the Call
Progress Tone Detector.
0~15
detect level 0 : –15dBm
(0) to –30dBm(15)
detect level 1 : –30dBm
(0) to –45dBm(15)
detect level 2 : –40dBm
(0) to –55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
Program