Issue 5.0 UNIVERGE SV8100
1 - 138 Call Duration Timer
Guide to Feature Programming
Operation
To time your trunk calls:
1. Place a trunk call.
. The timer starts automatically.
Program
Number
Program Name Description/Comments Assigned Data
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to extensions.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
20-09-06 Class of Service Options
(Incoming Call Service) –
Incoming Time Display
If this option is set to 1, the
Incoming Call Time is displayed on
the multiline terminals LCD while
the telephone is ringing.
0 = Off
1 = On
(default = 0 for COS
01~15)
20-13-36 Class of Service Options
(Supplementary Service) – Call
Duration Timer Display
In an extension Class of Service,
turn On (1) or Off (0) a Call Timer
for the extension.
0 = Off
1 = On
(default = 1 for COS
01~15)
21-01-03 System Options for Outgoing
calls – Trunk Interdigit Time
(External)
The time the system waits for this
time to expire before starting the
Call Timer.
0~64800 (seconds)
(default = 5 seconds)