1 - 210 Caller ID
When there are more than 20 characters set in Program 20-20 : Message Setup for
Non-Caller ID Data, either the first or last character is missing (based on the entry in
Program 20-19-01).
If Program 20-09-06: Class of Service Options (Incoming Call Service): Incoming Time
Display is set to 1 (On), the first line displays the time and date.
When you shut down the system, incoming history data is cleared. But you can back up the
history data by pressing Speaker +
# * # 9.
Program 15-07-01 button (63) when enabled, removes the CPN from the setup message
when making an outbound ISDN call, this is a toggle enable/disable button and can be
used on a Call-by-Call basis. Programs 14-01-20, 14-01-21 and 20-08-15 are used for
analog trunks only and can only be set on a per trunk/Class of Service basis.
SLT users cannot block an incoming call based on the incoming Caller ID information on a
station-by-station basis.
If command 15-02-57 is enabled, the Missed Call log will also display calls received whilst
the station was busy.
If the caller ID matches an abdial entry in program 13-04-01, the name associated with the
abdial entry in 13-04-02 is displayed on a Dterm.
If memo entries are added in programs 13-04-08~10 the additional information can be
displayed on a Dterm by pressing the right navigation key.