Issue 5.0 UNIVERGE SV8100
1 - 234 Central Office Calls, Answering
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
10-03-XX ETU Setup Use program 10-03-XX to setup
and confirm the basic
configuration data for each blade.
This program represents different
data depending on the blade
installed in the slot. Please refer
the SV8100 Programming Manual
for a more detailed description of
this program.
The assigned data
varies depending on
the blade installed in
the slot. Please refer
to the SV8100
Programming Manual
for a more detailed
description of the
10-03-XX programs.
11-11-13 Service Code Setup (for Setup/
Entry Operation) – Display
Language Selection for Multiline
Terminal
Select the service code which can
be used at an extension to change
the displayed language on a
multiline terminal display.
MLT
(default = 778)
11-12-30 Service Code Setup (for Service
Access) – Specified Trunk
Answer
If required, redefine the service
code used to answer a specific
trunk which is either ringing or on
hold.
MLT, SLT
(default = 772)
11-12-43 Service Code Setup (for Service
Access) – Universal Answer
If required, redefine the service
code used for Universal Answer.
MLT, SLT
(default = 872)
14-01-02 Basic Trunk Data Setup –
Transmit Level
Customize the transmit and
receive levels of the CODEC Gain
Types for each trunk.
Trunks 1~200
1~63
(-15.5 ~ +15.5dB in
0.5dB intervals)
[default = 32 (0dB)]
14-01-03 Basic Trunk Data Setup –
Receive Level
Customize the transmit and
receive levels of the CODEC Gain
Types for each trunk.
Trunks 1~200
1~63
(-15.5 ~ +15.5dB in
0.5dB intervals)
[default = 32 (0dB)]
14-02-02 Analog Trunk Data Setup – Ring
Detect Type
This option sets Extended Ring
Detect or Immediate Ring Detect
for the trunk. For T1 loop/ground
start trunks, this option must be
set to 1 for the trunks to ring and
light correctly.
Trunks 1~200
0 = Normal/delayed
1 = Immediate Ringing
(default = 1)
14-05-01 Trunk Group – Trunk Group
Number
Assign trunks to trunk groups then
go to Program 14-06-01 below to
set up Trunk Group Routing.
Trunks 1-200
Trunk Groups 1-100
Default = Trunks 1-200
assigned to trunk
group 1 with priorities
equal to the trunk
number.
Trunk 1 = Priority 1
Trunk 200 = Priority
200.

Table of Contents