UNIVERGE SV8100 Issue 5.0
Clock/Calendar Display 1 - 279
10-01-07 Time and Date – Second Enter two digits (00~59) for the
seconds.
00~59
(default not assigned)
10-24-01 Daylight Savings Setup –
Daylight Savings Mode
Enable (1) or disable (0) the
system ability to adjust the time for
daylight savings/standard time.
0 = Disable
1 = Enable
(default = 1)
10-24-02 Daylight Savings Setup – Time
for Daylight Savings
Enter the time of day the system
should adjust for daylight savings
time (0000~2359).
00:00~23:59
(default = 02:00)
10-24-03 Daylight Savings Setup – Start of
Month (Summer Time)
Enter the month of system should
adjust the time for daylight savings
time (01~12).
01~12
1 = Jan
2 = Feb, etc.
(default = 3)
10-24-04 Daylight Savings Setup – Start of
Week
Enter the week of the month the
system should adjust the time for
daylight savings time.
0~5
0 = Last Week of
Month
(default = 2)
10-24-05 Daylight Savings Setup – Start of
Week Day
Enter the day of the week the
system should adjust the time for
daylight savings time.
1~7
(1 = Sun, 2 =Mon, etc.)
(default = 1)
10-24-06 Daylight Savings Setup – End of
Month
Enter the month of system should
adjust the time for standard time.
01~12
(default = 11)
10-24-07 Daylight Savings Setup – End of
Week
Enter the week of the month the
system should adjust the time for
standard time.
0~5
0 = Last Week of the
Month
(default = 1)
10-24-08 Daylight Savings Setup – End of
Week Day
Enter the day of the week the
system should adjust the time for
daylight savings time.
1~7
(1 = Sun, 2 =Mon, etc.)
(default = 1)
20-02-07 System Options for Multiline
Telephones – Time and Date
Display Mode
Select the display mode (type 1~8)
for Time and Date (i.e., time and
date format).
1~8
Type 1 = (12 hour) 10
MAR TUE 3:15PM
Type 2 = (12 hour)
3:15PM MAR 10 TUE
Type 3 = (12 hour) 3-10
TUE 3:15 PM
Type 4 = (12 hour)
3:15PM TUE 10 MAR
Type 5 = (24 hour) 10
MAR TUE 15:15
Type 6 = (24 hour)
15:15 MAR 10 TUE
Type 7 = (24 hour) 3-10
TUE 15:15
Type 8 = (24 hour)
15:15 TUE 10 MAR
(default = 3)
Program
Number
Program Name Description/Comments Assigned Data

Table of Contents