Code Restriction In Credit 1 - 295
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
11-10-11 Service Code Setup (for System
Administration) – Code
Restriction in Credit
Assign a service code to be used
by the supervisor to set Code
Restriction in Credit
MLT
(default = 774)
11-11-33 Service Code Setup (for Setup/
Entry Operation) – Dial Block
Assign a service code to be used
for Dial Block.
MLT, SLT
(default = 700)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to extensions.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension ports =
Class 1
20-07-06 Class of Service Options
(Administrator Service)
Charging Cost Display
Turn off or on a supervisors ability
to set credits for code restriction in
credit.
0 = Off
1 = On
(default = 0 for
COS 1~15)
21-04-01 Toll Restriction Class for
Extensions
Use to assign a Toll Restriction
class to an extension for modes
1-8.
Day/Night Mode
1~9 (9 = Power Failure
Mode)
1~15
(default = 2)
21-05-01 Toll Restriction Class –
International Call Restriction
Table
For the Toll Restriction Class you
select, assigned (1) or unassigned
(0) the International Call Restrict
Table (Program 21-06-01).
0 = Unassigned (No)
1 = Assigned (Yes)
default:
1, 6~15 = 0
2~5 = 1
21-05-02 Toll Restriction Class –
International Call Permit Code
Table
For the Toll Restriction Class you
select, assign (1) or unassign (0)
the International Call Permit Table
(Program 21-06-02).
0 = Unassigned
1 = Assigned
default:
1, 3~15 = 0
2 = 1
21-05-04 Toll Restriction Class –
Maximum Number of Digits Table
Assignment
Select the table (defined in
Program 21-06-03) to be used to
determine the maximum number
of digits allowed for outgoing calls.
1~4 =Table
0 =Disable (None)
Default:
1, 2, 6~15 = 0
3 = 1
4 = 2
5 = 3
21-05-05 Toll Restriction Class – Common
Permit Code Table
It chooses whether the table set
up by Program 21-06-04 is
referred to, or not referred to.
0 = Unassigned
1 = Assigned
Default:
1, 8~15 = 0
2~7 = 1