UNIVERGE SV8100 Issue 5.0
Alarm Reports 1 - 27
Guide to Feature Programming
Setting Up Alarms:
Program
Number
Program Name Description/Comments Assigned Data
90-10-01 System Alarm Setup – Alarm
Type
Set the alarm type 14 and 60.
Alarm 14 – CD-CP00-LAN Link
Error (IP Layer 1)
Assign a Major or Minor alarm
status to the LAN link. This
program also assigns whether or
not the alarm is displayed to a key
telephone and whether or not the
alarm information is reported to
the predefined destination.
Alarm 57 - IP Duplication Alarm
Assign a Major or Minor alarm
status to the IP Duplication Alarm
Alarm 60 – SIP Registration
Error Notification
Assign a Major or Minor alarm
status to the SIP Registration
Error. This program also assigns
whether or not the alarm is
displayed to a key telephone and
whether or not the alarm
information is reported to the
predefined destination.
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
(default = 0)
90-10-02 System Alarm Setup – Report Assign whether or not the alarm is
displayed to a multiline terminal
and whether or not the alarm
information is reported to the
predefined destination in Program
90-11.
0 = No Report (no
autodial)
1 = Report (autodial)
(default = 0)
90-24-01 System Alarm Report
Notification Time Setup – Month
Set the month for the alarm report
to print.
Month 00~12
(0 = Disabled)
(default = 00)
90-24-02 System Alarm Report
Notification Time Setup – Day
Set the day for the alarm report to
print.
Day 00~31
(0 = Disabled)
(default = 00)
90-24-03 System Alarm Report
Notification Time Setup – Hour
Set the hour for the alarm report to
print.
Day 00~23
(0 = Disabled)
(default = 00)
90-24-04 System Alarm Report
Notification Time Setup – Minute
Set the minute for the alarm report
to print.
Day 00~59
(0 = Disabled)
(default = 00)