UNIVERGE SV8100 Issue 5.0
Facsimile CO Branch Connection 1 - 491
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
14-02-14 Analog Trunk Data Setup – Loop
Start/Ground Start
Select loop start (0) or ground start
(1) for the trunk.
0 = Loop Start (Loop)
1 = Ground Start
(Ground)
(default = 0)
14-02-21 FAX Branch Connection Sets CO for Fax Branch
Connection.
. If FAX Branch is selected,
Program 14-10 Power
Failure Telephone Setting is
NOT valid.
0 = No
1 = Yes
(default = 0)
14-05-01 Trunk Group Assign trunks to trunk groups
(1~100).
Trunk Group Number:
0~100
Priority Number:
1~200
(Default trunks 1~200
= Priority 1~200)
22-01-04 System Options for Incoming
Calls – DIL No Answer Recall
Time
A DIL that rings its programmed
destination longer than this
interval diverts to the DIL No
Answer Ring Group (set in
Program 22-08).
0~64800 (seconds)
(default = 0 seconds)
22-04-01 Incoming Extension Ring Group
Assignment
Assign extensions to ring groups. Maximum eight digits
Default:
Extensions 101~108
(first eight ports) ring
for incoming Ring
Group 1 calls. No
other extensions ring
for incoming Ring
Group 1 calls.
22-05-01 Incoming Trunk Ring Group
Assignment
To have the trunks ring
extensions, assign trunks to a
Ring Group. The incoming ring
group assignment programmed in
Program 41-03-01 overrides the
setting in this program.
Incoming Group
Number for Day/Night
Mode (1~8):
0 (No Setting)
001~100
(Incoming Group)
102 (In-Skin/ External
Voice Mail or InMail)
(default = 1)

Table of Contents