EasyManua.ls Logo

NEC Univerge SV8100 - Page 504

NEC Univerge SV8100
1174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 5.0 UNIVERGE SV8100
1 - 494 Flash
Guide to Feature Programming
Program
Number
Program Name Description/Comments Assigned Data
11-12-42 Service Code Setup (for Service
Access) – Flash on Trunk Lines
Use to customize the Service
Codes for flash on trunk lines.
SLT
(default = 806)
14-02-03 Analog Trunk Data Setup – Flash
Type
Make sure this item is set for open
loop Flash (0).
0 = Open Loop Flash
1 = Ground
(default = 0)
14-02-04 Analog Trunk Data Setup –
Hooking Type
For each trunk, indicate if Flash is
for Flash (0) or open loop
disconnect (1).
0 = Timed Flash
(Hooking)
1 = Disconnect (Cut)
(default = 0)
14-04-01 Behind PBX Setup For each trunk, indicate if the trunk
is installed behind a PBX.
0 = Stand Alone
(Trunk)
1 = Behind PBX (PBX)
2 = Not Used
3 = CTX assume 9
(default = 0)
15-03-04 Single Line Telephone Basic
Data Setup – Flashing
Enables/disables Flash for single
line telephones.
0 = No
1 = Yes
(default = 1)
81-10-07 COT Initial Data Setup –
Hookflash Time Selection 1
Set the Flash duration (16~4080
ms) for analog trunk CD-4COTB
circuits in Program 81-10-07.
0 = 20 ms
1 = 40 ms
2 = 60 ms
3 = 80 ms
4 = 100 ms
5 = 140 ms
6 = 160 ms
7 = 200 ms
8 = 400 ms
9 = 600 ms
10 = 800 ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 9 (600ms)]