UNIVERGE SV8100 Issue 5.0
Flexible Length DDI 1 - 499
Required Component(s)
v2.00 system software of later.
Related Features
Direct Inward Dialing (DID)
Department Calling
Guide to Feature Programming
Operation
None
Program
Number
Program Name Description/Comments Assigned Data
22-09-01 Expected number of digits
Enter the number of digits the
table expects to receive from the
telco. Use this program to make
the system compatible with 3- and
4-digit DID service.
(default = 4 digits)
22-09-06 Local Code
Enter the digits for Local Code in
overlap receive
(default not assigned)
22-09-07 Pilot Code
Enter the digit for Pilot Code.
(default not assigned)
22-09-08 T302 Time-out operation Assign whether the call is
disconnect or transferred on the
expiration of T302 timer.
(default = disconnect)
22-11 DID Translation Number
Conversion
Define the transfer the transfer
locations upon receipt of
matching DDI digits.
(default not assigned)
22-12 DID Intercept Ring Group Defines the fall over ring group for
DDI calls
(default = Incoming
Ring Group 1)
82-06-02 T302 Timer Defines the setting of ISDN timer
T302
(default = 10 seconds)