UNIVERGE SV8100 Issue 5.0
Flexible Timeouts 1 - 523
Conditions
Timer Classes are used for CAR/VE also.
When Timer Class is set to 0 it uses the system-wide timers.
All stations and trunks are assigned to Timer Class 0 at default.
Both system-wide timers (Timer Class 0) and Timer Class timers (Timer Class 1~15) can
be used in the same system.
Default Setting
Timer Class set to 0 for all trunks and extensions.
System Availability
Terminals
All Multiline Terminals
25-07-08 20-31-20 Long Conversation
Disconnect Time
This timer determines how long the system waits
before disconnecting a trunk-to-trunk conversation
call after the Long Conversation tone is heard.
Trunk Timer Class is referred.
25-07-09 20-31-21 DISA Internal Paging Time This is the maximum length of an Internal Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call. Trunk Timer Class is referred.
25-07-10 20-31-22 DISA External Paging Time This is the maximum length of an External Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call. Trunk Timer Class is referred.
31-01-02 20-31-23 Page Announcement
Duration
This timer sets the maximum length of External
Page announcements. Station or Trunk Timer
Class is referred by the caller makes
announcement.
Timer
Class 0
Timer
Class 1~15
Title Comment