Issue 5.0 UNIVERGE SV8100
1 - 536 Forced Trunk Disconnect
Guide to Feature Programming
Operation
To disconnect a busy trunk:
Multiline Terminal
1. Press line key for trunk.
- OR -
Dial trunk access code (805 + trunk number).
. You hear busy tone. Trunk numbers are 001~200.
2. Dial the Service Code (724).
. You hear confirmation beeps as the system disconnects the trunk.
. You can now place a call on the free trunk.
3. Press the line key for the trunk disconnected in Step 2.
Program
Number
Program Name Description/Comments Assigned Data
11-10-26 Service Code Setup (for System
Administrator) – Forced Trunk
Disconnect
Assign the Service Code. MLT, SLT
(default = 724)
20-06-01 Class of Service for Extensions Assign a Class of Service (COS)
to an extension. There are 15
Classes of Service that can be
assigned. Assign eight entries,
one for each Night Service Mode.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extensions = Class
1
20-07-11 Class of Service Options
(Administrator Level) – Forced
Trunk Disconnect (analog trunk
only)
Turns Off (0) or On (1) an
extension to use Forced Trunk
Disconnect. This allows the
extension to disconnect an
Unsupervised Conference in
progress.
0 = Off
1 = On
(default = 0 for
COS 1~15)
21-01-18 System Options for Outgoing
Calls – Reset Dial After Failure of
Trunk Access
Enable (1) or Disable (0) the ability
to continue to dial codes or
extensions after receiving Trunk
Busy. This needs to be set to
Enabled (1) for this feature to
work.
0 = Disable
1 = Enable
(default = 1)