Program
Number
Program Name Description/Comments Assigned Data
15-07-01 Programmable Function Keys Assign a function key for Hotline
(code 01 + partner’s extension
number).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
15-02-22 Multiline Telephone Basic Data
Setup – Multiple Incoming From
Intercom and Trunk
When this option is set to 0
(disabled), incoming calls to an
extension indicate on any Hotline
key for that extension as solid
(busy). When this option is set to
1 (enabled), lighting is determined
by the setting of Program
22-01-01 Incoming Call Priority. If
set to trunk priority (1), the Hotline
key lights solid when a trunk call
rings in. If set to intercom priority
(0), the Hotline key does not light
for incoming trunk calls, but lights
solid for intercom calls.
0 = Disable
1 = Enable
(default = 1)
20-06-01 Class of Service for Extensions Assign a Class of Service to
extensions (1~15).
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension ports =
Class 1
20-08-09 Class of Service Options
(Outgoing Call Service) –
Hotline/Extension Ringdown
Turn off or on hotline or ringdown
for extensions with this COS.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-08-19 Class of Service Options
(Outgoing Call Service) – Hotline
for SPK
Turn off or on an extensions’ ability
to activate hotline or ringdown
when pressing the Speaker key.
0 = Off
1 = On
(default = 0 for
COS 1~15)
20-11-06 Class of Service Options (Hold/
Transfer Service) – Unscreened
Transfer (Ring Inward Transfer)
Turns Off (0) or On (1) an
extension ability to use
Unscreened Transfer.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-11-11 Class of Service Options (Hold/
Transfer Service) – Automatic
On-Hook Transfer
Turn Off (0) or On (1) an extension
ability to use Automatic On-Hook
Transfer.
0 = Off
1 = On
(default = 0 for
COS 1~15)