Issue 5.0 UNIVERGE SV8100
1 - 654 Meet Me Conference
Programmable Function Keys
Guide to Feature Programming
. For additional programming for Paging, refer to the Paging External and Paging Internal features.
Operation
Meet Me External Conference
To make a Meet Me External Conference:
Multiline Terminal
1. While on a call, press Conf softkey.
2. Dial 751 and the Combined Paging Zone code 1~8 (for Internal/External Zones 1~8) or 0 (for
Program
Number
Program Name Description/Comments Assigned Data
15-07-01 Programmable Function Keys Assign function keys for
Conference (code 07).
Line Key 1~48
0~99 (Normal Function
Code 851 by default)
*00 ~ *99
(Appearance Function
Code) (Service Code
852 by default)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1
20-10-06 Class of Service Options
(Answer Service) – Meet-Me
Conference and Paging
Turns Off (0) or On (1) an
extension to use Meet-Me
Conference and Paging.
0 = Off
1 = On
(default = 1 for
COS 1~15)
31-01-04 System Options for Internal/
External Paging – Privacy
Release Time
Set the Privacy Release Time.
After the user initiates Meet Me
Conference, the system waits this
interval for the Paged party to join
the conversation.
0~64800 (seconds)
(default = 90 seconds)