Issue 5.0 UNIVERGE SV8100
1 - 754 (OPX) Off-Premise Extension
80-03-05 DTMF Tone Receiver Setup –
Forward Twist Level
Use this option to define the
forward twist level for DTMF Tone
Receiver.
0~9
(1dB ~ 10dB)
default:
Type 1 = 5 (6dBm)
Type 2 = 5 (6dBm)
Type 3 = 5 (6dBm)
Type 4 = 5 (6dBm)
Type 5 = 5 (6dBm)
80-03-06 DTMF Tone Receiver Setup –
Backwards Twist Level
Use this option to define the
backwards twist level for DTMF
Tone Receiver.
0~9
(1dB ~ 10dB)
default:
Type 1 = 0 (1dBm)
Type 2 = 0 (1dBm)
Type 3 = 0 (1dBm)
Type 4 = 0 (1dBm)
Type 5 = 0 (1dBm)
80-03-07 DTMF Tone Receiver Setup – ON
Detect Time
Use this option to define the On
detection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
Type 1 = 1 (30ms)
Type 2 = 1 (30ms)
Type 3 = 1 (30ms)
Type 4 = 1 (30ms)
Type 5 = 1 (30ms)
80-03-08 DTMF Tone Receiver Setup –
OFF Detect Time
Use this option to define the Off
detection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
Type 1 = 1 (30ms)
Type 2 = 1 (30ms)
Type 3 = 1 (30ms)
Type 4 = 1 (30ms)
Type 5 = 1 (30ms)
80-04-04 Call Progress Tone Detector
Setup – No Tone Time
Use to define the no tone time for
the Call Progress Tone Detector.
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
Program
Number
Program Name Description/Comments Assigned Data

Table of Contents