EasyManua.ls Logo

NEC Univerge SV8100 - Page 925

NEC Univerge SV8100
1174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 5.0
Speed Dial – System/Group/Station 1 - 915
80-03-03 DTMF Tone Receiver Setup –
Min. detect level
Use to define the minimum detect
levels for the DTMF Tone
Receiver.
0~15
detect level 0:
–10dBm(0) to
–25dBm(15)
detect level 1:
–15dBm(0) to –
30dBm(15)
detect level 2:
–20dBm(0) to –
35dBm(15)
detect level 3:
–25dBm(0) to –
40dBm(15)
detect level 4:
–30dBm(0) to –
45dBm(15)
detect level 5:
–35dBm(0) to –
50dBm(15)
detect level 6:
–40dBm(0) to –
55dBm(15)
detect level 7: -
45dBm(0) to -
60dBm(15)
detect level 8: -
50dBm(0) to -
65dBm(15)
detect level 9: -
55dBm(0) to -
70dBm(15)
detect level 10: -
60dBm(0) to -
75dBm(15)
detect level 11: -
65dBm(0) to -
80dBm(15)
detect level 12: -
70dBm(0) to -
85dBm(15)
detect level 13: -
75dBm(0) to -
90dBm(15)
detect level 14: -
80dBm(0) to -
95dBm(15)
detect level 15: -
85dBm(0) to -
100dBm(15) default:
Type 1 = 10 (-20dBm)
Type 2 = 15 (-25dBm)
Type 3~5 = 10
(-20dBm)
Program
Number
Program Name Description/Comments Assigned Data

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals