Issue 5.0 UNIVERGE SV8100
1 - 934 Station Hunt
Guide to Feature Programming
Operation
To make a Step Call:
1. Place a call to a busy extension.
Program
Number
Program Name Description/Comments Assigned Data
11-16-01 1 Digit Service Code Setup - Step
Call
Assign a single digit for step call SLT/MLT
Default not assigned
16-01-03 Department Group Basic Data
Setup – Department Routing
When Busy (Auto Step Call)
Assign if a call to busy station
hunts (1) or not hunts (0) to the
next available member of the Hunt
Group (Department Group).
. Refer Department Calling on
page 1-343 to set up the
Department Group.
0 = Normal (Intercom
caller to busy
department member
hears busy)
1 = Circular (Intercom
callers to busy
department member
routes to idle member)
(default = 0)
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1
20-09-07 Class of Service Options
(Incoming Call Service) – Call
Queuing
In an extension Class of Service,
turn On (1) or Off (0) Call Queuing
to the extension. This must be set
to (0) for Station Hunting to work.
0 = Off
1 = On
(default = 1 for
COS 1~15)
20-13-06 Class of Service Options
(Supplementary Service) –
Automatic Off-Hook Signaling
(Automatic Override)
In an extension Class of Service,
allows a busy extension to
manually (0) or automatically (1)
receive off-hook signals. This
must be set to (0) for Station
Hunting to work.
0 = Off
1 = On
(default = 1 for
COS 1~15)