UNIVERGE SV9100
Issue 1.0
5
A1
Correct AC Power
Problem.
Replace
Fuse(s).
Build system, one blade
at a
time until problem
reappears.
Replace
defective blade.
Done.
Yes
Build system
one
blade at a
time and
replace bad
blade(s).
1.
If problem not solved, perform First Initialization
and test. If
trouble persists go to step 2.
2.
Replace GCD-CP10 and test system
using default program.
Replace chassis.
Check AC Input
Power.
Turn system Off. Disconnect all connectors
and
remove all blades except GCD-CP10 and the first
installed GCD-8DLCA in the
controlling chassis
associated with the
programming station.
Replace Corresponding
Power
Supply.
Reset CD-8DLCA. If trouble
persists, replace
CD-8DLCA.
No internal Dial Tone to any Multiline Terminal or SLT
chassis panel lit on
GCD-CP10 or any other
blade?
No
Ye
s
Bad
AC Power?
Good
Bad
Dial
Tone
Turn system On.
Dial Tone on Multiline
Terminal on 1st
CD-8DLCA?
MPS7101
Fuses F1 and
F2 good?
Good
No Dial Tone
Yes
Problem
Solved?
Dial tone?
No
Remove all blades but
one GCD-8DLCA, and
retest.
Yes
No
Problem
Solved?
No