Issue 1.0
UNIVERGE SV9100
6
System Maintenance
A2
Correct AC Power
Problem.
Check
Station
Cabling.
Replace
Fuse(s).
Done.
Rebuild System one blade at
a time. If
problem reappears
replace defective
blade(s).
Build system
one
blade at a
time and
replace bad
blade(s).
1.
If problem not solved, perform First Initialization
and test. If
trouble persists go to step 2.
2.
Replace GCD-CP10and test system using
default program.
Replace chassis.
Check AC Input
Power.
Terminate one Multiline Terminal to
controlling
chassis, 1st CD-8DLCA
(Programming Station)
directly to MDF
and test.
Replace Corresponding
Power
Supply.
Reset CD-8DLCA. If trouble
persists,
replace CD-8DLCA.
No LED or Display Indications on any Multiline Terminal
Are LEDs on front of
chassis panel lit on
GCD-
CP10or any other
blade?
No
Yes
Bad
AC Power?
Yes
No
Terminal
Indications?
Turn system Off. Disconnect
connectors; remove all blades
except GCD-CP10and first
installed
CD-8DLCA in
controlling chassis,
associated
with the programming
station.
Good
Bad
MPS7101
Fuses F1 and F2 good?
Good
No Indication
Terminal
Installed
Indication?
Yes
Correct
Indication
Problem
Solved?
Correct
Indications?
No
Remove all blades but
one CD-8DLCA, and retest.
None
Yes
Problem
Solved?
No

Table of Contents