P 268 rev. 1.0 07-2006Technician Menu
2. Set parameters
2.2 Selections
2.2.1 Set water
2.2.1.1 Water doses
2.2.1.2 Set whipper
2.2.1.2.1 Set whip doses
2.2.1.2.2 Set modality
2.2.1.3 El.valve setting
2.2 Selections
2.2.1 Setting the water
2.2.1.1 Water doses
With this function the water dose can be set for each selec-
tion button, expressed in:
- cc for Fresh-Brew and Instant models
- flow-meter pulses for Espresso models
the display will indicate the name of the product being set for
each product included in the selection.
2.2.1.2 Setting the whipper
2.2.1.2.1 Setting the whipper doses
The whipping time can be set for each selection button, for
each water dose that composes such selection.
The duration can be set in two different modes:
2.2.1.2.2 Setting the whipper mode
It is possible to choose between two different modes:
Absolute
i.e. independent from the solenoid valve opening time. The
whipping duration is set as tenths of a second for Instant
models and as volumetric counter pulses for Espresso models.
Relative
i.e. based on the difference, plus or minus, from the moment
the solenoid valve closes.
The whipping duration is always expressed in tenths of a
second.
2.2.1.3 Solenoid valve settings
It is possible to set the water flow rate of the single solenoid
valves expressed in cc/s (the default value setting in cc/s is
indicated in the selection dose table) to calculate the amount
of water to be dispensed in Fresh-Brew and Instant models.