P 268 rev. 1.0 07-2006Technician Menu
1. Failures
1.1 Failure reading
1. Failures
1.1 Reading the failures
When the “Failure” function is displayed, press the confirm
button “ ” to display the present failures.
If no failures are currently present, after pressing the confirm
button “ ” the message “End failures” will be displayed.
The possible failures are indicated in the following cases:
Water failure
If the air-break micro-switch is closed for more than one
minute, the water inlet solenoid valve will remain energized
until the water flow is restored.
Waste container full
The machine locks if the liquid waste container float is trig-
gered.
Air-break
The machine is locked if after 10 selections the micro-switch
has never signalled the lack of water.
Volumetric counter
Failed computation of the volumetric counter within a maxi-
mum given time.
Boiler
The machine will lock if after the maximum time of heating
from the machine start, or from the last selection, the boiler
fails to reach the operating temperature.
CAN-BUS board
Failed dialogue between C.P.U. board and CAN-BUS board
(Fresh-brew unit control).
Coin mechanism
The machine is locked if it receives a pulse longer than 2
seconds on a validator line or the communication with the
serial coin mechanism does not take place for more than 30
seconds (Executive protocol) or 75 seconds (BDV protocol).
Grinder blockage
If the coffee grinder does not rotate or rotates too slowly for
longer than 5 seconds, the espresso coffee selections are
disabled. Decaffeinated coffee based selections remain available.
Coffee unit
Due to mechanical blocking of the unit. The machine is not
locked, but all coffee-based selections are disabled.
No coffee
If the coffee grinder exceeds the speed of 1200 RPM for
longer than 5 seconds, the espresso coffee based selections are
disabled. Decaffeinated based selections remain available.
RAM Data
One or more areas of the RAM contain wrong data which was
corrected with the default values.
The machine will continue to function, but it would be advis-
able to initialise as soon as possible.
Water failure
Waste container full
Air-break
Volumetric counter
Boiler
CAN-BUS board
Coin mechanism
Coffee unit
Grinder
RAM data
No coffee