P 268 rev. 1.0 07-2006Technician Menu
4. Test
4.3 Autotest
4.3 Autotest
This function allows testing, in a semiautomatic way, of the
main machine components.
When pressing the confirm button, the message “AUTOTEST”
will be start blinking.
It is possible to cancel each operation and go to the next one
by pressing the exit button, but confirming with the confirm
button to start the autotest routine.
Some checks occur automatically, others need the manual
operation of the monitored component.
In a sequence:
- the mixers are activated for 2 seconds
- the mixers are activated for 2 seconds
- rotation of the brewer unit
- wash button; the machine awaits until the button is pressed.
- waste container switch; the machine awaits until the waste
container micro-switch is manually operated
- push-button panel test; the machine will display the number
of the button which must be pressed and awaits the actuation
before going to the next button
- boiler temperature reading
- triggering of a sound signal
- coin mechanism test; checking that communication with the
coin mechanism takes place correctly and which validator lines
are set as being active.