to be observed. Any functional faults, especially those affecting the safety of the machine,
are to be rectied immediately.
• For E-PAK 500 to function properly and full the necessary safety requirements as stated
in the declaration of conformity, the complete system is to be assessed with regards to
applicable safety standards and directives and comply with all requirements described in
this document.
• The designer of the system as a whole, has to guarantee the correct function of all
interacting products or components and ensure that the complete system meets all
necessary safety requirements.
• Only authorized personnel is allowed to have access to this unit.
4 Description
4.1 Function
E-PAK 500 has been designed to lter non-combustible dust and welding fumes in a high
vacuum system.
E-PAK 500 is a complete vacuum unit with a direct-driven side channel fan tted as one unit
on a steel frame and a start and control unit with an integrated 24 V transformer. E-PAK 500 is
Y/D started. The unit has automatic start/stop and automatic lter cleaning in two stages.
Filtration in two stages
In the rst stage, the inlet separates course particles. In the second stage, ne particles are
separated on lter bags.
Automatic lter cleaning
E-PAK 500 uses lter cleaning by a short blast of reversed air ow with atmospheric pressure.
By the rapid opening of the lter cleaning valve located on top of the lter, a powerful blast of
reversed air ow is created, efciently dislodging dust from the lter bags.
Figure 3shows the function of E-PAK 500 according to the following:
1. Air ow during normal operation and collection of dust.
2. Air with atmospheric pressure released into the lter during lter cleaning.
3. Short blast of reversed air ow during lter cleaning.
4. Filter cleaning valve.
4.2 Dimensions
For the dimensions of E-PAK 500, see Figure 1, 2 and 6.