FlexPAK 800/1000
11
EN
3.1.3 Running (Running mode)
The unit in Running mode. The pump motor is on and the unit generates a vacuum. The
FCV is closed. The current vacuum of the unit is shown on the display, for example, -20 kPa.
ESC OK
Running
kPA -20
DIRTm 00:00 s
OTTmr 00:00 h
Exhaust
Air Temp 60°C
DIRTm: The amount of me before the unit goes into Idling mode. The
default is 10 seconds. See also Secon ‘4.2.7 DIR_Time’.
OTTmr: If the Overme mer has been acvated, OTTmr shows the
elapsed me since the overme mer started.
The temperature of the exhaust air is displayed at the boom of the
display.
3.1.4 FlexPAK Idling (Idling mode)
The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open.
The unit goes into Idling mode when there has been no pilot signal for the me set in DIR_
Time, see Secon ‘4.2.7 DIR_Time’.
ESC OK
FlexPak
Hi Vacuum Unit
IDLING
Time To StandBy
05:33m
TimeToStandby: The amount of me unl the unit goes into Standby
mode. The default seng is 12 minutes. See Secon ‘4.2.4 SSR_Time’.
3.1.5 Filter Cleaning
The unit is cleaning its lter.
ESC OK
Filter
Cleanining
Cycles 1
Elapsed 0
Clean 00:00 s
Charge 00:00 s
Cycles: How many cleaning pulses will be carried out.
Elapsed: How many cleaning pulses are made.
Clean: Remaining me for cleaning pulse.
Charge: Remaining vacuum build me; the me unl cleaning pulse is
acvated.
3.1.6 Emptying preseparator
The me remaining unl the preseparator bin is to be emped.
ESC OK
EMPTYING
Preseparator
Bin 1 08:00s
Bin 2 06:00s
Bin 1: The me remaining to empty the preseparator as set in BinOpnTm.
Bin 2: The me remaining for preseparator 2 to be emped as set in
PresepTm.
3.1.7 Open Upper Slide Valve V12
The message appears when the TVFD Upper Solenoid Valve is expected to open. The mer
is set with TVFDO-Al, see Secon ‘4.2.39 MFDPS-Al’. If the mer elapses, the ‘TVFD Alarm!
Upper Slide Not Open is acvated. This message is only shown when TVFD advanced is
acvated.
ESC OK
Open Upper
Slide Valve
Remaing time
06:00s
Remaining Time: The remaining me for the valve to open before the
alarm is acvated.