FlexPAK 800/1000EN
22
4.2.2 Set the weekly mer
Weekly mer sets the unit to “Stand By” mode and “O Mode” at preset mes. If the pilot
signal “PS” is acve and the Vacuum unit is in Standby mode, the unit starts.
ESC OK
Thu 10:45
2018-02-01
ESC OK
Stop >
Program >
Setup >
Network >
Diagnoscs >
ESC OK
Set Parameter
Program Name
ESC OK
WeekTmr 1/2
D1 = MTWTF
On1 = 00:00
Off1 = -- --
D2 = MTWTF
On2 = -- --
ESC OK
WeekTmr 2/2
Off2 = -- --
D3 = - - - - -SS
On3 = -- --
Off3 = -- --
Pulse = Off
ESC OK
FlexPak
Hi Vacuum Unit
OFF
Time To Service
2000 hours
ESC OK
WeekTmr >
PresepTm >
MFDPS-Wr >
MFDPS-FC >
BLI-Empt >
BLI-Wr Z
Do the following to set the weekly mer:
1. From the PLC status screen, press the down arrow to go to the date and me
screen.
2. Press ‘Escape’
ESC
to go to the main menu.
3. Press the down arrow to go to ‘Program’. Press ‘OK’
OK
to conrm.
4. Select ‘Set Parameter’. Press ‘OK’
to conrm.
5. Use the up or down arrows to nd ‘WeekTmr’. Press ‘OK’
OK
to conrm.
6. Use right, le, up and down arrows to select a value and change
sengs. Press ‘OK’
OK
to conrm.
NOTE! There are several other input menus on the same level as the date and me screen.
If pressing the down arrow
takes the PLC to one of those menus, use the le arrow
to get to the date and me screen.
Daily AM seng
ESC OK
WeekTmr 1/2
D1 = - - - - - - -
On1 = -- : --
Off1 = -- : --
D2 = - - - - - - -
On2 = -- : --
D1: = MTWTF: Default seng; Monday, Tuesday, Wednesday, Thursday
and Friday.
On1 = Time the unit is set to ‘Standby’ at chosen D1 days. Default seng
is no preset me.
O1 = The me the unit is set to ‘O’ on chosen D1 days. Default seng
is no preset me.
Daily PM seng
ESC OK
WeekTmr 1/2
D1 = - - - - - - -
On1 = -- : --
Off1 = -- : --
D2 = - - - - - - -
On2 = -- : --
D2 = MTWTF: Default seng; Monday, Tuesday, Wednesday, Thursday
and Friday.
On2 = Time the unit is set to ‘Standby’ at chosen D2 days. Default seng
is no preset me.
O2 = The me the unit is set to ‘O’ on chosen D2 days. Default seng
is no preset me.