FlexPAK 800/1000
27
EN
4.2.18 PSCFlush
Menu for acvang ushing of the duct system. When ‘Switch=O’, ushing is mer
controlled. When ‘Switch=On’, ushing is contolled by the pilot signal; ushing takes place
when the pilot signal dissapears. See Secons ‘4.2.32 PSIFC’ and ‘4.2.34 FlushTmr’.
ESC OK
PSCFlush 1/1
Switch = Off
Switch=O is the default seng. PSCFlush is deacvated.
To acvate PSCFlush set Switch=On.
4.2.19 BinAuto
Menu for acvang the Automac Emptying of collector Bin interval Timer (AEBTme), see
Secon ‘4.2.14 AEBTme’.
ESC OK
BinAuto 1/1
Switch = Off
Switch=O is the default seng; the BinAuto mer is o.
To acvate the AEBTme mer, set Switch=On.
4.2.20 LiAuto
Menu for acvang Bin Level Indicator Automac Emptying of Bin (BLI-Empt), see Secon
‘4.2.12 BLI-Empt’.
ESC OK
LIAuto 1/1
Switch = Off
Switch=O is the default seng; LiAuto is deacvated
To acvate LiAuto, set Switch=On.
4.2.21 LSOTmr
Menu for seng the amount of me the TVFD Solenoid Lower Valve (SLV) is open for bin
emptying. LSOTmr is only used if TVFDAdv is acvated (Switch=On). This message is only
used when TVFD advanced is acvated
NOTE! LSOTmr cannot be set to a value equal to or greater than TVFDO-Al,
LSOTmr < TVFDO-Al.
ESC OK
LSOTmt 1/1
T = 10:00s
Ta = 00:00s
T=10:00s: Amount of me the SLV to be open. The default seng is 10
seconds.
Ta=00:00: The elapsed me since SLV has been opened.
4.2.22 FlushCy2
Menu for seng the amount of me for automac ushing of the duct system by ushing
valve 2 (SFV2). FlushCy2 is acvated by FlushCy1. ‘T’ is how long ushing valve 2 is open.
ESC OK
FlushCy2 1/1
T = 10:00s
Ta = 00:00s
T=10:00s: Time ush valve 2 (SFV2) is open. The default seng is 10
seconds.
Ta=00:00: The elapsed me since the ushing cycle started.