COMFORT FUNCTIONS
AUXILIARY BACKUP HEATING
OFPP = Off peak period
SYSTEM 4
Solar system
with Solar
pump speed
control,
HYDraulic
and Electric
auxiliary
heating
R2 (HYD)
MAX R1=OFF
T3<T2Set
MAX+BOOST
-
R3 (ELEC)
ECO+BOOST -
SYSTEM 10
Solar system
with Smart
Hydraulic
auxiliary
heating from
Solid fuel boiler
and Electric
auxiliary
heating
R2 (HYD)
MAX R1=OFF
T4>T4Min
+
T3<T2Set
MAX+BOOST
-
T3<T2Set
R3 (ELEC)
ECO+BOOST -
R2=OFF
+
T3<T2Set
+
T4<T4Min
MAX+OFPP R1=OFF
SYST4
HYPC
SYST10
HYSF
R3
R3
R1
R1
Auxiliary
backup
type
Triggering conditions for auxiliary backup heating
Mode
27