NMC-PRO
INSTALLATION GUIDE
Doc. Name: NMC-PRO
׀
Installation Manual Revision: 2 Page: 22
Crop Management Technologies
Digital Inputs (Menu 8.1.2)
Function: Define the input function according to the physical wiring location on the card
(see Hardware Layout page 6). Place the cursor on the relevant line and press
ENTER, a selection list will open, choose the appropriate sensor and press
ENTER to confirm.
#: Define the input's number (per zone or WS-Weather Station). This will be the
reference number for all other menus concerning this sensor.
Zone: Define Zone number or WS for location of sensor.
NOTE: This table refers to both local and extension boxes.
Test Digital Inputs (Menu 6.3)
The Digital Input Test screen displays the current state of the input in the VALUE column.
When the VALUE column displays a "1" then the contact of the input is currently closed
.
Whereas a "0" represents that the contact is currently open
.
8.1.2. Install DI
19/01/09 16:21
Input Function # Zone
1
2
3
4
5
6
7
8
9
10
11
Local
Local
Local
Local
Local
Local
Local
Local
Ext
Ext
Ext
Wind Speed
Extern. Contact
Rain Detector
Rain Collector
Vent Opened
Vent Closed
Screen Spread
Screen Collected
None
None
None
1
1
1
1
1
1
1
1
0
0
0
WS
Zone1
WS
WS
Zone1
Zone1
Zone1
Zone1
None
None
None
6.3. DI test
19/01/09 16:21
Input
Function
#
Value
1
2
3
4
5
6
7
8
9
10
11
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
LOCAL
N/A
N/A
N/A
Wind Speed
Extern. Contact
Rain Detector
Rain Collector
Vent Opened
Vent Closed
Screen Spread
Screen Collected
None
None
None
1
1
1
1
1
1
1
1
0
0
0
0
1
0
0
1
0
0
0
0
0
0