EasyManua.ls Logo

Netafim NMC PRO CLIMATE - STATUS - VENT (MENU 4.1)

Netafim NMC PRO CLIMATE
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NMC-PRO
INSTALLATION GUIDE
Doc. Name: NMC-PRO
׀
Installation Manual Revision: 2 Page: 23
Crop Management Technologies
Analog Inputs (Menu 8.1.3)
Function: Define the input function according to the physical wiring location on the card
(see Hardware Layout page 6). Place the cursor on the relevant line and press
ENTER, a selection list will open, choose the appropriate sensor and press
ENTER to confirm.
#: Define the input's number (per zone or WS-Weather Station). This will be the
reference number for all other menus concerning this sensor.
Zone: Define Zone number or WS for location of sensor.
NOTE: This table refers to both local and extension boxes.
Test Analog Inputs (Menu 6.2)
The Analog Test displays the sensors A/D readings, 0 1023
Sensor type Description
Humidity sensor
RH% = 0; A/D = 0
RH% = 50; A/D = 308
RH% = 100; A/D = 620
Temp sensor
T°C = 0; A/D = 768
T°C = 25; A/D = 489
T°C = 50; A/D = 250
8.1.3. Install AI 19/01/09 16:21
Input
Function
#
Zone
1
2
3
4
5
6
7
8
9
10
11
Local
Local
Local
Local
Local
Local
Local
Local
Local
Local
Local
Temp. In
Temp. Out
None
None
None
None
Radiation
None
Humidity Out
Humidity In
Wind Dir
1
1
0
0
0
0
1
0
1
1
1
Zone1
WS
None
None
None
None
WS
None
WS
Zone1
WS
6.2. AI test
19/01/09 16:21
Input Function # Value
1
2
3
4
5
6
7
8
9
10
11
Local
Local
Local
Local
Local
Local
Local
Local
Local
Local
Local
Temp. In
Temp. Out
None
None
None
None
Radiation
None
Humidity Out
Humidity In
Wind Dir
1
1
0
0
0
0
1
0
1
1
1
496
575
1023
192
0
118
174
1
382
303
526

Other manuals for Netafim NMC PRO CLIMATE