Doc. Name: NMC-PRO
Installation Manual Revision: 2 Page: 23
Crop Management Technologies
Analog Inputs (Menu 8.1.3)
• Function: Define the input function according to the physical wiring location on the card
(see Hardware Layout page 6). Place the cursor on the relevant line and press
ENTER, a selection list will open, choose the appropriate sensor and press
ENTER to confirm.
• #: Define the input's number (per zone or WS-Weather Station). This will be the
reference number for all other menus concerning this sensor.
• Zone: Define Zone number or WS for location of sensor.
NOTE: This table refers to both local and extension boxes.
Test Analog Inputs (Menu 6.2)
The Analog Test displays the sensors A/D readings, 0 – 1023
Sensor type Description
Humidity sensor
RH% = 0; A/D = 0
RH% = 50; A/D = 308
RH% = 100; A/D = 620
Temp sensor
T°C = 0; A/D = 768
T°C = 25; A/D = 489
T°C = 50; A/D = 250
8.1.3. Install AI 19/01/09 16:21
2
3
4
5
6
7
8
9
10
11
Local
Local
Local
Local
Local
Local
Local
Local
Local
Local
Temp. Out
None
None
None
None
Radiation
None
Humidity Out
Humidity In
Wind Dir
1
0
0
0
0
1
0
1
1
1
WS
None
None
None
None
WS
None
WS
Zone1
WS
Input Function # Value
2
3
4
5
6
7
8
9
10
11
Local
Local
Local
Local
Local
Local
Local
Local
Local
Local
Temp. Out
None
None
None
None
Radiation
None
Humidity Out
Humidity In
Wind Dir
1
0
0
0
0
1
0
1
1
1
575
1023
192
0
118
174
1
382
303
526