NMC-PRO
INSTALLATION GUIDE
Doc. Name: NMC-PRO
׀
Installation Manual Revision: 2 Page: 27
Crop Management Technologies
Vent (Menu 8.2.1)
# Parameter Explanation Unit/Range Default
1.
Vent Type
Define the control that the Vent is
connected to.
1-6
2.
Vent Control
Define the Vent Type: Top1 - 4, LSide, ESide,
and None.
Top1
3.
Vent Direction
Define the direction of the vent in degrees,
relative to the north (this parameter is used
to decide if the vent is lee or wind)
0-360
o
--
4.
Vent Position
when Fan&Pad
Event starts
Define the position of the vent when a
Fan&Pad event starts.
0-100% 0%
5.
Minimum Vent
Position with
Fan&Pad
Define the minimum vent position to enable
the Fan&Pad.
0-100% 0%
6.
Opening Run
Time
Define the amount of time the vent takes
from fully CLOSED to fully OPEN
mm:ss 02:00
7.
Closing Run
Time
Define the amount of time the vent takes
from fully OPEN to fully CLOSED
mm:ss 02:00
8.
Running Delay
Define the delay time, the time it takes from
applying the open/close command until the
operation starts
mm:ss 00:01
9.
Extra Run Time
The extra time after the vent is fully CLOSED
(0%) or fully OPENED (100%) to make sure
that the vent is completely opened or closed
mm:ss 00:20
8.2.1. Vent cfg.
Zone 1
19/01/09 16:21
1.
Vent #
2. Controlled by
3. Vent direction°
4. Position w F&P %
5. Min vent w F&P %
6. Open time mm:ss
7. Close time mm:ss
8. Run delay mm:ss
9. Extra run time
10. Calib. Curve
11. Wind pos w Frost
12. Lee pos w Frost
1
Top1
0
50
20
02:00
02:00
00:00
00:03
0
0
2
LSide
90
50
20
02:00
02:00
00:00
00:03
0
0
3
ESide
180
50
20
02:00
02:00
00:00
00:03
0
0